4D Image Verification / Nejlevnější knihy
4D Image Verification

Kód: 01621036

4D Image Verification

Autor Christian Schaller

Diploma Thesis from the year 2007 in the subject Computer Science - Applied, grade: 1,0, Friedrich-Alexander University Erlangen-Nuremberg (Lehrstuhl für Mustererkennung), 66 entries in the bibliography, language: English, abstrac ... celý popis

1506


Skladem u dodavatele
Odesíláme za 15-20 dnů
Přidat mezi přání

Mohlo by se vám také líbit

Dárkový poukaz: Radost zaručena

Objednat dárkový poukazVíce informací

Více informací o knize 4D Image Verification

Nákupem získáte 151 bodů

Anotace knihy

Diploma Thesis from the year 2007 in the subject Computer Science - Applied, grade: 1,0, Friedrich-Alexander University Erlangen-Nuremberg (Lehrstuhl für Mustererkennung), 66 entries in the bibliography, language: English, abstract: Far reaching developments and technical advances took place within the field of radiotherapy in the last years. Radiotherapy within the chest and abdomen area is especially important in the field of radiotherapy. Within this regions, organ and tumor positions are significantly affected by patient respiration. The tumor motion, caused due to respiration is compensated by extending the treated area. This extension covers all possible positions of the tumor and therefore also includes healthy tissue.Several clinical studies provide evidence of a survival advantage for higher dose levels. To spare a maximum of healthy tissue physicians use gated radiotherapy . Common recent approaches for gated radiotherapy are based on the observation of a surrogate. This either can be an implanted fiducial marker or an external signal, which is trying to capture the patients respiration.Within this thesis principles and methods of gated radiotherapy are described. Additionally an overview of recent patents and products related to radiotherapy are presented and advantages and disadvantages of both common approaches are discussed. This discussion leads to a new developed method, which is introduced. The method joins advantages of both known methods but disregards their disadvantages. The developed algorithm is using image guided methods and methods of medical image processing. A mapping between a 4D-CT planning volume and a most recent acquired fluoroscopic sequence of the same patient is calculated before treatment. Using this mapping and an external breathing signal the physician can define gating intervals and treat the patient in certain breathing phases.The developed algorithm is included in an existing prototype developed by Siemens Corporate Research (SCR) in Princeton, NJ, USA. Using this prototype, the application of the method is shown. Furthermore another prototype to acquire respiration synchronized fluoroscopic sequences is developed. Both applications are introduced within this thesis.

Parametry knihy

Zařazení knihy Knihy v angličtině Computing & information technology Business applications

1506

Oblíbené z jiného soudku



Osobní odběr Praha, Brno a 12903 dalších

Copyright ©2008-24 nejlevnejsi-knihy.cz Všechna práva vyhrazenaSoukromíCookies


Můj účet: Přihlásit se
Všechny knihy světa na jednom místě. Navíc za skvělé ceny.

Nákupní košík ( prázdný )

Vyzvednutí v Zásilkovně
zdarma nad 1 499 Kč.

Nacházíte se: